Performance test of faulty distribution transformers along. Insulation power factor testing of power transformers. Apply voltage through a variac on the open secondary of the ct and measure magnetizing current on the secondary. A typical excitation current test data pattern for a threelegged core is two similar current. Tan delta test loss angle test dissipation factor test electrical4u. It also gives an idea of the aging process in the cable. The current from the device under test is compared to the current of an internal reference capacitor. Check that all parts of the transformer are properly assembled and tight. Tan delta test for transformer free download as word doc. Current transformers play an important role in the monitoring and protection of electrical power systems. In this article we are going to discuss in detail about transformer winding tan delta test. Basics, maintenance, and diagnostics vii contents continued page 4. Check nameplate ratings and hv, lv terminal markings. Very low frequency vlf tan delta testing is a precise and nondestructive method to provide information on the extent of ageing in cable insulation.
The megger delta4000 tan delta tester has two configurations. Accepting that there are not established, well proven standards for pd or tan delta testing, and both are best used on a. Magnetization and primary injection test of current transformer for protective relaying jacob tsado 8 current transformers. The tan delta results, along with other knowledge of the cables history, and possibly other test data like partial discharge, all help to give us some guidance. Capacitance and tan delta test of transformer made in. Repeat the test for the other phases and the other secondary cores. Sfra testing on transformers electrical test equipment. The latest sfra test sets make these techniques more accessible, more convenient and. For three phase deltawye or wyedelta transformer, a three phase equivalency test is performed, i. Tm 5686 power transformer maintenance and acceptance. Stores up to 50 records onboard and download to pc. Tan delta test of transformer full procedure explained step by step in detail. The winding insulation of three phase transformers is typically measured together for all three. How do we know if a cable is good, marginal, or bad.
The procedure of the transformer ratio test is simple. This test is done 1to ensure the dielectric strength of insulation or 2to predict the life of bushing. Dissipation factor, power factor, and relative permittivity dielectric constant by i. Iec 60247 innovative test cell easy to assemble and clean. In order to inject appropriate currents, care must be taken regarding protected power transformer rating data and main ct connections which are used for this particular installation.
Our distribution transformer test system dtts has been designed with these requirements in mind, as a multifunctional tool for testing distribution transformers. By using the latest proven sfra test techniques, it is possible to accurately assess transformer condition without dismantling it. General inspection mechanical checks general visual inspection and compliance with the drawings and manuals. Transformer testing type tests and routine tests of. Also know as power factor and dissipation factor testing, these state of the art instruments give the user a wide range of results for qualitative cable assessments such as degradation and lifetime estimations on mv and hv systems. The cable, winding, current transformer, potential transformer, transformer bushing, on which tan delta test or dissipation factor test to. Also information about some types of transformers are gathered as well as distribution transformer connections installations. There are various test required on transformer to conform performance of transformer. The test system is comprised of the cpc 100 multifunction primary test system and the cp td1 tangent delta unit. Shorted turntoturn insulation, short circuited core laminations, loosening of the core clamping, or.
Instrument transformer theory and testing steve hudson, pe. With regards to your statement relating to whether tan delta testing could have any adverse effect on transformer health, the following. If there are no recognized standards for tan delta test values, what good is the test. Cts are instrument transformers used for converting primary current into a reduced secondary current for use with meters, relays, control equipment and other instruments the importance of instrument transformer tests is often underestimated. Tan delta test for transformer capacitor electrical resistance.
The contents of this manual are the property of megger sweden. Also there is detailed analysis about the consisting of a distribution transformer. Answer praveen tan delta, also called loss angle or dissipation factor testing, is a diagnostic method of testing cables to determine the quality of the cable insulation. Threephase transformer testing method and system enabling convenient performance of ansirequired checking of polarity and phaserelation and also enabling measurements of core loss, load loss and transformer ratio to be performed conveniently. Testing power transformers highvoltage transformers are some of the most important and expensive pieces of.
First of all the current generated during the differential stability test is calculated using the % z voltage and source to feed the current will have to be chosen. Tan delta test loss angle test dissipation factor test. The oil tan delta otd is a laboratory instrument, which measures the tan delta, resistivity and relative permittivity of insulating liquids. Dissipationpower factor measurement tan delta on instrument. High voltage onsite power transformer testing ee publishers.
A transformer is a device used to change the voltage levels of electricity to facilitate the transfer of electricity from generating stations to. So transformer ratio test is an essential type test of transformer. Testing of power transformers seems like a similar experience. The core of a transformer is made of iron whereas thewinding which is wrapped over. The default test configuration is the ust ungrounded specimen test measurement, in which the transformer. Tan delta this test is also known as the loss tangent or dielectric dissipation factor. Loss angle or dissipation factor testing, is a diagnostic method of. This test also performed as a routine test of transformer. Apply the 440 vac supply from hv side of the transformer in such way that primary cts are included in the circuit. Partial discharges in transformers are typically measured by applying a prespecified voltage to the transformer windings and measuring induced charges via a coupling device e. Cvtccvt capacitive coupled voltage transformer typically used for voltages 69 kv 765 kv 1200 kv in india.
Important note regarding partial discharge versus tan delta. Transformer design drytype and cast resin, protection methods are being referred and more also included in the specific research document. The eltel automatic capacitance and tan delta test sets operate on the transformer ratio arm bridge principle. Insulation power factor testing of power transformers oleh w. In a pure capacitor current leads the voltage by 90 degrees. Advantages and disadvantages of tan measurements as a function of voltage source. The cable, winding, current transformer, potential transformer, transformer bushing, on which tan delta test or dissipation factor test to be conducted, is first isolated from the system. Sfra testing on transformers dismantling a power transformer to determine its condition is hardly ever a practical possibility. A very lowfrequency test voltage is applied across the equipment whose insulation to be tested. Losses of transformersthe transformers are made of 2 types of materials. According to 3 sfra method determines the transformer responses in a time or frequency area.
Iwanusiw, consultant eltel industries, bangalore, india. Magnetization and primary injection test of current. In a perfect capacitor, the voltage and current are phase shifted 90 degrees and the current through the insulation is capacitive. It is used to measure the deterioration in the cable. Current transformers testing and commissioning guidelines. Cts should be tested before they are mounted on the transformer. Transformer bushing tan delta test is similar to the ct tan delta test and lnk to the artivle on ct tan delta test is. Diagnostic testing of high voltage insulation for conditionmonitoring. Transformer oil testing by robert turcotte, manager, electrical loss control the hartford steam boiler inspection and insurance company the value of transformer oil testing transformer oil testing is a proven loss prevention technique which should be a part. Given in the appendix are several procedures that can be used to test the. Provides voltage potential for revenue meters and sometimes protection circuits capacitive divider down to 512 kv followed by a standard inductive stepdown voltage transformer to typically 115 v. Procedure all windings immersed in insulating liquid. Buy megger delta4000 tan delta tester ireland powerpoint. So for ensuring proper performance of electrical power transformer, voltage and turn ratio test of transformer one of the important tests.
The residual of this comparison is measured and resolved into inphase watt loss and quadrature current components. The tags should be highly visible, and as many people as possible should be made aware of their presence before the work begins. The ultimate testing system for transformer diagnosis. When a resistor is introduced in between the current leads an angle less than 90 degrees. Tan delta test sets, which come as both standalone and vanmounted systems, are increasingly common components in todays test procedures. There is a relationship between the dissipation factor, the power factor, and the permittivity or dielectric. Mainly two types of transformer are done by manufacturer before dispatching the transformer mainly 1 type test of transformer and 2 routine test. In addition some other tests are also carried out by the consumer at site before commissioning and also periodically. In this book we have laid down important aspects on transformer testing in order to enhance the understanding of the testing. Transformer bushing cts should be tested using the current ratio test method before the transformer has been completely assembled. Tan delta is a a diagnostic test conducted on the insulation of cables and winding. A presentation ontransformer testing using dpatt3bi 2. It is correct to say that there is not an extensive library of test values for all types.
Transformer test ing allows this aging process to be quantified and. Tan delta test for transformer capacitor electrical. The power factor in a circuit is defined as the ratio of power to voltamperes w va. Herewith some information relating to tan delta power factor and capacitance test on transformers from our perspective. Transformer is the most important equipment in the electrical power transmission and distribution system.
Connection on cpc100 will be same as the shown figure. This presentation includes a definition of terms, outlines measurements and calculations to be. Power factor is also defined as the cosine of the angle between the voltage and. Tan delta, also called loss angle or dissipation factor testing, is a diagnostic method of testing cables to determine the quality of the cable insulation.
1213 616 959 1436 1452 987 1479 422 47 1035 814 1367 1345 1178 572 1415 137 153 492 101 367 319 1008 1241 595 1086 1416 1340 100 1115 899 115 396 27 761 5 1267